psiNAT ChikungunyaReal Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from Chikungunya virus from whole blood, plasma, serum samples. Chikungunya virus (CHIKV), is a member of the genus Alphavirus, and family Togaviridae.It is an RNA virus with a positive-sense single-stranded genome of about 11.6kb. Chikungunya is generally transmitted from mosquitoes to humans. psiNAT Chikungunya Real Time RT-PCR Test kit targets the specific conserved sequence encoding Chikungunya virus poly protein gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | poly protein gene of Chikungunya virus |
Specimen | Whole Blood, Plasma, Serum |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96,QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT DengueReal Time RT-PCR Test kitfor the qualitative/ quantitative detection of nucleic acid from Dengue virus from whole blood, plasma, serum samples.Dengue fever is a mosquito- borne tropical disease caused by the dengue virus. Dengue infection is caused by any one of the four related serotypes of the Dengue virus (DEN1, DEN-2, DEN-3 or DEN-4).Depending on the immune response, Dengue infection is classified as primary or secondary. psiNAT Dengue Real Time RT-PCR Test kit targets the specific conserved sequence encoding Dengue poly gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument.The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | polygene of Dengue |
Specimen | Whole Blood, Plasma, Serum |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Leptospira Real Time PCR Test kit for the qualitative/ quantitative detection of nucleic acidfrom Leptospira from whole blood, serum, plasma, urine samples of suspected individuals.Leptospirosis is a bacterial disease that affects humans and animals. It is caused by bacteria of the genus Leptospira. The bacteria that cause leptospirosis are spread through the urine of infected animals, which can get into water or soil and can survive there for weeks to months. psiNAT Leptospira Real Time PCR Test kit targets the specific conserved sequence encoding Leptospira 16S rRNA gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | 16S rRNA gene of Leptospira |
Specimen | whole blood, serum, plasma, urine |
Specificity | Influenza B subtypes B/Victoria lineage, B/Yamagata lineage |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96,QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Malaria Real Time PCR Test kitfor the qualitative/ quantitative detection of nucleic acid fromPlasmodium parasites from whole blood, plasma, serum samples.Malaria is a serious and sometimes fatal disease caused by parasite that commonly infects a certain type of mosquito which feeds on humans. P. falciparum is the type of malaria that is most likely to result in severe infections and if not promptly treated, may lead to death. psiNAT Malaria Real TimePCR Test kit targets the specific conserved sequence encoding Plasmodium ribososmal gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument.The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | Ribosomal gene of PlasmodiumWhole Blood, Plasma, Serum |
Specimen | Whole Blood, Plasma, Serume |
Specificity | Plasmodium falciparum, Plasmodium vivax, Plasmodium malariae, Plasmodium ovale and Plasmodium knowlesi |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Fever Multiplex Panel Real Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from Chikungunya virus, Dengue virus, West Nile virus, Zika virus, Leptospira, Plasmodium parasites, Salmonella Typhi, Japanese Encephalitis [JE] and Orientia tsutsugamushi from whole blood, plasma, serum, urine samples. This test refers to a multiplex testdone to identify the pathogen behind fever and other symptoms. Doctors can make decision accordingly to stop or prevent the progression of the disease with this test.psiNAT Fever Multiplex Panel Real Time RT-PCR Test kit targets the specific conserved sequence encoding poly protein gene of Chikungunya virus, Dengue poly gene, West Nile virus poly protein gene, Zika virus (ZIKV) poly gene, Leptospira 16S rRNA gene, Plasmodium ribosomal gene, ttrRSBCA locus of Salmonella, Japanese EncephalitisNS2A gene andScrub typhus htrA gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | poly protein gene of Chikungunya virus, Dengue poly gene, West Nile virus poly protein gene, Zika virus (ZIKV) poly gene, Leptospira 16S rRNA gene, Plasmodium ribosomal gene, ttrRSBCA locus of Salmonella, Japanese EncephalitisNS2A gene, Scrub typhus htrA gene |
Specimen | Whole Blood, Plasma, Serum |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC, RED/ROX , Cy5 channels |
Storage | Room Temperature |
Number of tubes for a test | 2 |
Vial Label | Pathogen Detected |
T1 | Dengue, Chikungunya, ZIKA |
T2 | Leptospira, Plasmodium spp, JE |
T3 | Salmonella, West Nile Virus, Rickettsia spp |
psiNAT SalmonellaReal Time PCR Test kit for the qualitative/ quantitative detection of nucleic acid from Salmonella typhifrom whole blood, plasma, serum samples. Salmonella enterica typhiis family Enterobacteriaceae. Salmonella species are non-spore-forming, predominantly motile enterobacteria with cell diameters between about 0.7 and 1.5 μm, lengths from 2 to 5 μm, and peritrichous flagella. Typhoid fever caused by Salmonella enterica Typhi continues to be a major health problem in spite of the use of antibiotics and the development of newer antibacterial drug. psiNAT Salmonella Real Time PCR Test kit targets the specific conserved sequence encodingttrRSBCA locus of Salmonella. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | ttrRSBCA locusof Salmonella enterica typhi |
Specimen | Whole Blood, Plasma, Serum |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Scrub typhus Real Time PCR Test kit for the qualitative/ quantitative detection of nucleic acid from Orientia tsutsugamushifrom whole blood, plasma, serum samples. Scrub typhus is a mite-borne infectious disease caused by the obligate intracellular bacterium Orientia tsutsugamushi. A characteristic feature of the disease is patients presenting nonspecific symptoms, including fever, headache, myalgia, cough, and abdominal pain, which cannot be differentiated from symptoms of other systemic infections. psiNAT Scrub typhus Real Time PCR Test kit targets the specific conserved sequence encoding Scrub typhus htrA gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | htrA gene of Scrub typhus |
Specimen | Whole Blood, Plasma, Serum |
Specificity | O. tsutsugamushi, R. africae, R. sharonii, R. parkeri, and R. rhicpicephali |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT West Nile Real Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from West Nile virus from whole blood, plasma, serum samples. West Nile (WN) virus is an arthropod-borne virus that is taxonomically classified within the family Flaviviridae, genus Flavivirus.The virus possesses a single-stranded plus-sense RNA genome of approximately 11,000 nucleotides. WN virus circulates in natural transmission cycles involving primarily Culex species mosquitoes and birds, and humans are incidental hosts.psiNAT West Nile Real Time RT-PCR Test kit targets the specific conserved sequence encoding West nile virus poly protein gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | poly protein gene of West Nile virus |
Specimen | Whole Blood, Plasma, Serum |
Specificity | West Nile virus L1 and L2 |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNATZika virus (ZIKV) Real Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from Zika virus (ZIKV) virus from whole blood, plasma, serum samples.Zika virus (ZIKV) is an arbovirus Flaviviridae family genus flavivirus transmitted by domestic mosquitoes Aedes aegypti.ZIKV is a single-stranded RNA virus with a positive-polarity RNA genome of approximately 11 kb. psiNATZika virus (ZIKV) Real Time RT-PCR Test kit targets the specific conserved sequence encoding Zika virus (ZIKV)poly gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | poly protein gene of Zika virus (ZIKV) |
Specimen | Whole Blood, Plasma, Serum |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Streptococcus agalactiae Real Time PCR Test kit for the qualitative detection of nucleic acidfrom whole blood, and CSFsamples of suspected individuals.Streptococcus agalactiae, also referred as Lancefield group B Streptococcus (GBS), is a leading cause of bacterial meningitis and sepsis in neonates and an important cause of disease among pregnant women. In recent years, GBS has also been recognized as an emerging cause of invasive bacterial infections in adults.psiNATStreptococcus agalactiae Real Time PCR Test kit targets the specific conserved sequence encoding Streptococcus agalactiae cfd gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | cfd gene of Streptococcus agalactiae |
Specimen | whole blood and CSF |
Specificity | Streptococcus agalactiae |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Streptococcus pneumoniae Real Time PCR Test kit for the qualitative detection of nucleic acidfrom whole blood, and CSFsamples of suspected individuals.Pneumococcal meningitis is caused by Streptococcus pneumoniae bacteria (also called pneumococcus, or S pneumoniae).This type of bacteria is the most common cause of bacterial meningitis in adults. It is the second most common cause of meningitis in children older than age 2.psiNATStreptococcus pneumoniae Real Time PCR Test kit targets the specific conserved sequence encoding Streptococcus pneumoniae lytAgene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | lytA gene of Streptococcus pneumoniae |
Specimen | whole blood and CSF |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Varicella-zoster Real Time PCR Test kit for the qualitative detection of nucleic acid from whole blood, and CSF samples of suspected individuals. Varicella-zoster virus (VZV), also known as human herpesvirus 3 (HHV-3, HHV3) or Human alphaherpesvirus 3, is one of nine known herpes viruses that can infect humans. It causes chickenpox (varicella) which is an acute infectious disease. psiNAT Varicella-zoster Real Time PCR Test kit targets the specific conserved sequence encoding Varicella-zoster ORF gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | ORF gene of Varicella-zoster |
Specimen | Whole blood and CSF |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
• Pathogen: Japanese Encephalitis Virus (JEV)
• Transmission: Mosquito bites
• Symptoms: Fever, headache, vomiting, neurological symptoms
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |