psiNAT Covid-19 Real Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from SARS-CoV-2 from upper and lower respiratory specimens(nasopharyngeal swabs ,nasal swabs , dual nasopharyngeal/throat swabs and lower respiratory tract specimens including bronchoalvolar lavage , bronchial wash ,tracheal aspirate ,sputum, and lung tissue. Covid-19 is a contagious disease caused by a virus, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). COVID-19 is mainly transmitted when people breathe in air contaminated by droplets/aerosols and small airborne particles containing the virus. Infected people exhale those particles as they breathe, talk, cough, sneeze, or sing. Transmission is more likely the more physically close people are. psiNAT Covid-19 Real Time RT-PCR Test kit targets the specific conserved sequence encoding the ORF 1ab genes of SARS-CoV-2. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | ORF 1ab gene of SARS-CoV-2 |
Specimen | upper and lower respiratory specimens |
Specificity | SARS-CoV-2 |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Influenza A Real Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from Influenza A from upper and lower respiratory specimens(nasopharyngeal swabs ,nasal swabs , dual nasopharyngeal/throat swabs and lower respiratory tract specimens including bronchoalvolar lavage , bronchial wash ,tracheal aspirate ,sputum, and lung tissue. Influenza A viruses are negative-sense, single-stranded, segmented RNA viruses. Because the surface proteins of influenza A are highly mutable, infection with this type is associated with pandemic disease in humans. psiNAT Influenza A Real Time RT-PCR Test kit targets the specific conserved sequence encoding the M1 & M2 genes of Influenza A. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | M1 & M2 gene of Influenza A |
Specimen | upper and lower respiratory specimens |
Specificity | Influenza A subtypes H1N1,H3N2 |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96,QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT Influenza B Real Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from Influenza A from upper and lower respiratory specimens(nasopharyngeal swabs ,nasal swabs , dual nasopharyngeal/throat swabs and lower respiratory tract specimens including bronchoalvolar lavage , bronchial wash ,tracheal aspirate ,sputum, and lung tissue. Influenza B viruses are members of the Orthomyxoviridae family of RNA viruses, circulate in humans, and cause respiratory illness every year. psiNAT Influenza B Real Time RT-PCR Test kit targets the specific conserved sequence encoding the M1 & BM2 genes of Influenza B. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | M1 & M2 gene of Influenza B |
Specimen | upper and lower respiratory specimens |
Specificity | Influenza B subtypes B/Victoria lineage, B/Yamagata lineage |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96,QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNATRespiratory Multiplex Panel Real Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from respiratory specimens(nasopharyngeal swabs,nasal swabs, dual nasopharyngeal/throat swabs and lower respiratory tract specimens including bronchoalvolar lavage, bronchial wash,tracheal aspirate,sputum, and lung tissue od suspected patients. Respiratory infection is a type that affects the lungs and other parts of the respiratory system, which can be due to virus or bacteria. psiNATRespiratory Multiplex PanelReal Time RT-PCR Test kit is for the detection ofSARS-CoV-2, Influenza A, Influenza B, Respiratory Syncytial Virus A&B, Streptococcus pneumonia, Klebsiella pneumoniaand targets the specific conserved sequence encoding theORF 1ab genes of SARS-CoV-2,M1 & M2 gene of Influenza A, M1 & BM2 gene of Influenza B, polymerase gene of Respiratory syncytial virus, lytA gene of Streptococcus pneumoniaeandphoEgene ofKlebsiella pneumonia. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | theORF 1ab genes of SARS-CoV-2,M1 & M2 gene of Influenza A, M1 & BM2 gene of Influenza B, polymerase gene of Respiratory syncytial virus, lytA gene of Streptococcus pneumoniae, phoEgene ofKlebsiella pneumonia |
Specimen | upper and lower respiratory specimens |
Specificity | Influenza A subtypes H1N1,H3N2 |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96,QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
Number of tubes for a test | 2 |
Vial Label | Pathogen Detected |
T1 | Influenza A, Influenza B, SARS CoV-2 |
T2 | RSV-A&B, Streptococcus pneumonia, Klebsiella pneumonia |
psiNAT RSV A&B Real Time RT-PCR Test kit for the qualitative/quantitative detection of nucleic acid from Respiratory syncytial virus from upper and lower respiratory specimens(nasopharyngeal swabs ,nasal swabs,dual nasopharyngeal/throat swabs and lower respiratory tract specimens including bronchoalvolar lavage , bronchial wash ,tracheal aspirate ,sputum, and lung tissue. Respiratory syncytial virus (RSV), also called human respiratory syncytial virus (hRSV)and human orthopneumovirus, is a common, contagious virus that causes infections of the respiratory tract. It is a negative-sense, single-stranded RNA virus. Based on genetic and antigenic variations in the structural proteins, RSV is classified into two subgroups, A and B. psiNAT RSV A&B Real Time RT-PCR Test kit targets the specific conserved sequence encoding the polymerase genes of Respiratory syncytial virus . With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Technology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | polymerise gene of Respiratory syncytial virus |
Specimen | upper and lower respiratory specimens |
Specificity | RSV A and B |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96,QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
• Pathogen: Legionella pneumophila
• Transmission: Inhalation of aerosolized water droplets
• Symptoms: Pneumonia, fever, chills, cough
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |