psiNAT MDR TB Real Time PCR Test kit for the qualitative/quantitative detection of nucleic acidSputum, BAL, swab, urine, CSF, plasma, stool samples of suspected individuals.Multidrug-resistant tuberculosis (MDR-TB) is a form of tuberculosis (TB) infection caused by bacteria that are resistant to treatment with at least two of the most powerful first-line anti-TB medications (drugs), isoniazid and rifampin. The TB bacteria has natural defenses against some drugs, and can acquire drug resistance through genetic mutations.Resistance to anti-TB drugs can occur when these drugs are misused or mismanaged. Major spread is through air droplets originating from a person who has the disease either coughing, sneezing, speaking, or singing. psiNAT MDR TB Real Time PCR Test kit targets the specific conserved sequence encoding rpoBgene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
FeaturesTechnology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | MDR TB rpoB gene |
Specimen | Sputum, BAL, swab, urine, CSF, plasma, stool samples |
Specificity | Rifampin resistant MDR TB |
Sensitivity | 95% |
Traceability | 1st WHO International Standard for HPV DNA genotypes |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
psiNAT MTB Real Time PCR Test kit for the qualitative/quantitative detection of nucleic acidSputum, BAL, swab, urine, CSF, plasma, stool samples of suspected individuals. Mycobacterium tuberculosis (M. tb) is a species of pathogenic bacteria in the family Mycobacteriaceae and the causative agent of tuberculosis. M.tuberculosis was found in a complex in 2019 that has at least 9 members: M. tuberculosis sensustricto, M. africanum, M. canetti, M. bovis, M. caprae, M. microti, M. pinnipedii, M. mungi, and M. orygis.Major spread is through air droplets originating from a person who has the disease either coughing, sneezing, speaking, or singing. psiNAT MTB Real Time PCR Test kit targets the specific conserved sequence encoding M. tb IS6110 gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
FeaturesTechnology | Real-time PCR, Ready to use test |
Configuration | 10 Test/ Kit with 2 positive and negative controls |
Target Sequence | M. tb IS6110 gene |
Specimen | Sputum, BAL, swab, urine, CSF, plasma, stool samples |
Specificity | M.tuberculosis , M. africanum, M. bovis |
Sensitivity | 95% |
Traceability | 1st WHO International Standard for HPV DNA genotypes |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
• Pathogen: Toxoplasma gondii
• Transmission: Ingestion of oocysts from contaminated food/water or undercooked meat
• Symptoms: Flu-like symptoms, severe cases in immunocompromised individuals
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
• Pathogen: Chlamydia psittaci
• Transmission: Inhalation of infected bird droppings or respiratory secretions
• Symptoms: Pneumonia, fever, chills
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
• Pathogen: African Sleeping Sickness
• Transmission: Tsetse fly bites
• Symptoms: Fever, headaches, sleep disturbances, neurological symptoms
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
• Pathogen: Monkeypox
• Transmission: Animal bites, person-to-person contact
• Symptoms: Fever, rash, swollen lymph nodes
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
• Pathogen: Naegleria fowleri
• Transmission: Freshwater exposure (swimming, neti pots)
• Symptoms: Severe headache, fever, stiff neck, confusion
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |
• Pathogen: Babesia microti
• Transmission: Tick bites (Ixodes scapularis)
• Symptoms: Fever, chills, sweats, hemolytic anemia
Technology | Real-time PCR, Ready to use test |
Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
Sensitivity | 95% |
Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
Storage | Room Temperature |