psiNAT 3H(HIV, HBV, HCV) MultiplexReal Time RT-PCR Test kit is a combo PCR kit for the qualitative/ quantitative detection of nucleic acid from Human Immunodeficiency virus, Hepatitis B virus and Hepatitis C virus from whole blood, plasma, serum samples.Human immunodeficiency virus infection and acquired immunodeficiency syndrome (HIV/AIDS) is a spectrum of conditions caused by infection with the human immunodeficiency virus (HIV), a retrovirus.Hepatitis B is an infectious disease caused by the hepatitis B virus (HBV) that affects the liver; it is a type of viral hepatitis.Hepatitis C (HCV) is an infection that causes scarring in the liver and reduces function in this vital organ. psiNAT3H (HIV, HBV, HCV) MultiplexReal Time PCR Test kit targets the specific conserved sequence encoding thepol and gaggene of HIV 1/2, Pgene of HBV and Poly gene of HCV.With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time 4 channel PCR instrument.The PCR detection system includes an endogenous internal control too.
Features
Technology
Real-time RT-PCR (4 channel), Ready to use test
Configuration
10 Test/ Kit with 2 positive and negative controls
Target Sequence
pol and gag gene of HIV 1/2, Pgene of HBV, Poly gene of HCV
Specimen
Whole Blood, Plasma, Serum
Specificity
HIV subtypes A, B, C, D, A/E, F, G, AG-GH, N, O, J, CRF HBV genotype A-H HCV genotype 1-6
Sensitivity
95%
Traceability
4th WHO International Standard for HIV-1 RNA
2nd WHO International Standard for HIV-2 RNA
4th WHO International Standard for HBVDNA
6th WHO International Standard for HCV RNA
Instrument Compatibility
Compatible with Applied Biosystems (ABI) 7500, BioRad CFX 96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC, RED/ROx, Cy5 channels
Storage
Room Temperature
HBV
Introduction
psiNAT HBV Real TimePCR Test kitfor the qualitative/ quantitative detection of nucleic acid from Hepatitis B virus from whole blood, plasma, serum samples.Hepatitis B is an infectious disease caused by the hepatitis B virus (HBV) that affects the liver; it is a type of viral hepatitis. It can cause both acute and chronic infection.psiNAT HBVReal Time PCR Test kit targets the specific conserved sequence encoding the P gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument.The PCR detection system includes an endogenous internal control too.
Features
Technology
Real-time PCR, Ready to use test
Configuration
10 Test/ Kit with 2 positive and negative controls
Target Sequence
P gene of HBV
Specimen
Whole Blood, Plasma, Serum
Specificity
HBV genotype A-H
Sensitivity
95%
Traceability
4th WHO International Standard for HBV DNA
Instrument Compatibility
Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels
Storage
Room Temperature
HCV
Introduction
psiNAT HCV Real Time RT-PCR Test kit for the qualitative/ quantitative detection of nucleic acid from Hepatitis C virus from whole blood, plasma, serum samples. Hepatitis C (HCV) is an infection that causes scarring in the liver and reduces function in this vital organ. psiNAT HCV Real Time RT-PCR Test kit targets the specific conserved sequence encoding the poly gene. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument. The PCR detection system includes an endogenous internal control too.
Features
Technology
Real-time PCR, Ready to use test
Configuration
10 Test/ Kit with 2 positive and negative controls
Target Sequence
P gene of HCV
Specimen
Whole Blood, Plasma, Serum
Specificity
HCV genotype A-H
Sensitivity
95%
Traceability
4th WHO International Standard for HCV DNA
Instrument Compatibility
Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels
Storage
Room Temperature
HIV 1 & 2
Introduction
psiNATHIV 1&2Real Time RT-PCR Test kitfor the qualitative/ quantitative detection of nucleic acid from Human Immunodeficiency virus from whole blood, plasma, serum samples.Human immunodeficiency virus infection and acquired immunodeficiency syndrome (HIV/AIDS) is a spectrum of conditions caused by infection with the human immunodeficiency virus (HIV), a retrovirus. psiNATHIV1&2Real Time RT-PCR Test kit targets the specific conserved sequence encoding the pol and gaggene of HIV- 1&2. With the PCR reaction mix provided, the amplification of template can be quantitatively monitored by the increasing fluorescence signal detected by a real-time PCR instrument.The PCR detection system includes an endogenous internal control too.
Features
Technology
Real-time PCR, Ready to use test
Configuration
10 Test/ Kit with 2 positive and negative controls
Target Sequence
pol and gaggene of HIV-1&2
Specimen
Whole Blood, Plasma, Serum
Specificity
HIV subtypes A, B, C, D, A/E, F, G, AG-GH, N, O, J, CRF
Sensitivity
95%
Traceability
4th WHO International Standard for HIV-1 RNA
2nd WHO International Standard for HIV-2 RNA
Instrument Compatibility
Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96,QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels